Fluke 117C

Fluke 117C

Fluke 117C True RMS Multimeter, CAT III 600 V environments

0 Phản hồi ROHS

Nhà sản xuất: Fluke

Liên hệ đặt hàng

Số lượng mua

899 lượt xem

Bảng giá

Số lượng
(Cái)
Giá(VND)
1
4,650,000
3
4,550,000
5
4,450,000
10
4,350,000

Sản xuất tại Trung Quốc


Designed by electricians. Engineered by Fluke.

The compact Fluke 117 true RMS digital multimeter is optimized to help you keep commercial buildings, hospitals and schools running right.

The advanced features of the Fluke 117 help you get the job done, quickly and safely. Integrated non-contact voltage detection helps you identify energized circuits. The AutoV/LoZ function prevents false readings caused by ghost voltage. The Fluke 117 delivers true-rms ac voltage and current readings with 6000-count resolution. It provides Min/Max/Average readings and measures frequency and capacitance. The battery door is easy to access, so you and your Fluke 117 can stay on the job.

Fluke 117 multimeters are independently tested for safe use in CAT III 600V environments.

And check out other members of the Fluke 110 family: Fluke 113 Utility Multimeter, the Fluke 114 Electrical Multimeter, the Fluke 115 Multimeter and the Fluke 116 HVAC Multimeter with Temperature and Microamps.

  • VoltAlert™ technology for non-contact voltage detection
  • AutoVolt automatic ac/dc voltage selection
  • Low input impedance: helps prevent false readings due to ghost voltage
  • Large white LED backlight to work in poorly lit areas
  • True-rms for accurate measurements on non-linear loads
  • Measures 10 A (20 A overload for 30-seconds)
  • Resistance, continuity, frequency and capacitance
  • Min/Max/Average with elapsed time to record signal fluctuations
  • Compact ergonomic design for one-handed operation
  • Compatible with optional magnetic hanger (ToolPak™) for hands free operation
  • CAT III 600 V safety rated
Specifications
Maximum voltage between any terminal and earth ground
   600 V
Surge protection
   6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2
Fuse for A input
   11 A, 1000 V FAST Fuse (Fluke PN 803293)
Display
Digital:  6,000 counts, updates 4 per second
Bar graph
   33 segments, updates 32 per second
Operating Temperature
   -10 °C to + 50 °C
Storage Temperature
   -40 °C to + 60 °C
Battery type
   9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery Life
   400 hours typical, without backlight
Accuracy Specifications
DC millivolts
Range:  600.0 mV
Resolution:  0.1 mV
Accuracy:  ± ([% of reading] + [counts]): 0.5% + 2
DC volts
Range/Resolution:  6.000 V / 0.001 V
Range/Resolution:  60.00 V / 0.01 V
Range/Resolution:  600.00 V / 0.1 V
Accuracy:  ± ([% of reading] + [counts]): 0.5% + 2
Auto volts
Range:  600.0 V
Resolution:  0.1 V
Accuracy:  2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz)
AC millivolts1 true-rms
Range:  600.0 mV
Resolution:  0.1 mV
Accuracy:  1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
AC volts1 true-rms
Range/Resolution:  6.000 V / 0.001 V
Range/Resolution:  60.00 V / 0.01 V
Range/Resolution:  600.0 V / 0.1 V
Accuracy:  1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
Continuity
Range:  600 Ω
Resolution:  1 Ω
Accuracy:  Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer.
Ohms
Range/Resolution:  600.0 Ω / 0.1 Ω
Range/Resolution:  6.000 kΩ / 0.001 kΩ
Range/Resolution:  60.00 kΩ / 0.01 kΩ
Range/Resolution:  600.0 kΩ / 0.1 kΩ
Range/Resolution:  6.000 MΩ / 0.001 MΩ
Accuracy:  0.9 % + 1
Range/Resolution:  40.00 MΩ / 0.01 MΩ
Accuracy:  5 % + 2
Diode Test
Range/Resolution:  2.000 V / 0.001 V
Accuracy:  0.9% + 2
Capacitance
Range/Resolution:  1000 nF / 1 nF
Range/Resolution:  10.00 μF / 0.01 μF
Range/Resolution:  100.0 μF / 0.1 μF
Range/Resolution:  9999 μF / 1 μF
Range/Resolution:  100 μF to 1000 μF
Accuracy:  1.9% + 2
Range/Resolution:  > 1000 μF
Accuracy:  5% + 20%
LoZ capacitance
Range:  1 nF to 500 μF
Accuracy:  10% + 2 typical
AC amps true-rms (45 Hz to 500 Hz)
Range/Resolution:  6.000 A / 0.001 A
Range/Resolution:  10.00 A / 0.01 A
Accuracy:  1.5% + 3
   20 A continuous overload for 30 seconds max
DC amps
Range/Resolution:  6.000 A / 0.001 A
Range/Resolution:  10.00 A / 0.01 A
Accuracy:  1.0% + 3
   20 A continuous overload for 30 seconds max
Hz (V or A input)2
Range/Resolution:  99.99 Hz / 0.01 Hz
Range/Resolution:  999.99 Hz / 0.1 Hz
Range/Resolution:  9.999 Hz / 0.001 Hz
Range/Resolution:  50.00 Hz / 0.01 Hz
Accuracy:  0.1% + 2

Notes:
1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F

Mechanical & General Specifications
Size
   167 x 84 x 46 mm (6.57" x 3.31" x 1.82")
Weight
   550 g
Warranty
   3 years

Model includes the following:

  • 4 mm silicone test lead set
  • Holster
  • User manual