Fluke 115

Fluke 115

Large white LED backlight, Resistance and continuity, Frequency and capacitance, Maximum Voltage ac/dc 600V

0 Phản hồi ROHS

Nhà sản xuất: Fluke

Liên hệ đặt hàng

Số lượng mua

771 lượt xem

Bảng giá

Số lượng
(Cái)
Giá(VND)
1
4,390,000
3
4,290,000
5
4,190,000
10
4,090,000

Sản xuất tại Trung Quốc


For general purpose electrical and electronic test requirements, the Fluke 115 true-rms digital multimeter provides the perfect answer. Its simple operation, compact design and ease of use makes it perfect for quick verifications and field service use.

 

The Fluke 115 displays true-rms voltage and current readings with 6000 count resolution, tests diodes, frequency, continuity and capacitance and provides Min/Max/Average readings to record signal fluctuations. A large white LED backlight aids work in poorly lit areas. Its easy-open battery access door makes battery changes a snap.

Fluke 115 multimeters are independently tested for safe use in CAT III 600V environments.
And check out other members of the Fluke 110 family: the Fluke 113 Utility Multimeter, the Fluke 114 Electrical Multimeter, the Fluke 116 HVAC Multimeter and the Fluke 117 Commercial Electrician’s Multimeter.

 

Also check out the Fluke 114 Electrical Multimeter, the Fluke 116 HVAC Multimeter with Temperature and Microamps, and the Fluke 117, the Electrician’s Multimeter with Non-contact voltage

  • Large white LED backlight to work in poorly lit areas
  • Resistance and continuity
  • Frequency and capacitance
  • Maximum Voltage ac/dc 600V
  • 10A ac/dc current measurement (20 A overload for 30-seconds max)
  • Min/Max/Average to record signal fluctuations
  • CAT III 600 V safety rated

Safety conformance

All inputs are protected to CE, IEN61010-1 CAT III 600V. UL, CSA, TÜV listed and VDE.

Specifications
Maximum voltage between any terminal and earth ground
   600 V
Surge protection
   6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2
Display
Digital:  6,000 counts, updates 4 per second
Bar graph
   33 segments, updates 32 per second
Operating Temperature
   -10 °C to + 50 °C
Storage Temperature
   -40 °C to + 60 °C
Battery type
   9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery Life
   400 hours typical, without backlight
Accuracy Specifications
DC millivolts
Range:  600.0 mV
Resolution:  0.1 mV
Accuracy:  ± ([% of reading] + [counts]): 0.5% + 2
DC volts
Range/Resolution:  6.000 V / 0.001 V
Range/Resolution:  60.00 V / 0.01 V
Range/Resolution:  600.00 V / 0.1 V
Accuracy:  ± ([% of reading] + [counts]): 0.5% + 2
AC millivolts1 true-rms
Range:  600.0 mV
Resolution:  0.1 mV
Accuracy:  1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz)
AC volts1 true-rms
Range/Resolution:  6.000 V / 0.001 V
Range/Resolution:  60.00 V / 0.01 V
Range/Resolution:  600.0 V / 0.1 V
Accuracy:  1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz)
Continuity
Range:  600 Ω
Resolution:  1 Ω
Accuracy:  Beeper on < 20 Ω, off > 250 Ω; detectsopens or shorts of 500 μs or longer.
Ohms
Range/Resolution:  600.0 Ω / 0.1 Ω
Range/Resolution:  6.000 kΩ / 0.001 kΩ
Range/Resolution:  60.00 kΩ / 0.01 kΩ
Range/Resolution:  600.0 kΩ / 0.1 kΩ
Range/Resolution:  6.000 MΩ / 0.001 MΩ
Accuracy:  0.9 % + 1
Range/Resolution:  40.00 MΩ / 0.01 MΩ
Accuracy:  5 % + 2
Diode Test
Range/Resolution:  2.00 V / 0.001 V
Accuracy:  0.9% + 2
Capacitance
Range/Resolution:  1000 nF / 1 nF
Range/Resolution:  10.00 µF / 0.01 µF
Range/Resolution:  100.0 µF / 0.1 µF
Range/Resolution:  9999 µF / 1 µF
Range/Resolution:  100 µF to 1000 µF
Accuracy:  1.9% + 2
Range/Resolution:  > 1000 µF
Accuracy:  5% + 20%
Lo-Z Capacitance
Range:  1 nF to 500 µF
Accuracy:  10% + 2 typical
AC amps true-rms (45 Hz to 500Hz)
Range/Resolution:  6.000 A / 0.001 A
Range/Resolution:  10.00 A / 0.01 A
Accuracy:  1.5% + 3
   20 A overload for 30-seconds max
DC amps
Range/Resolution:  6.000 A / 0.001 A
Range/Resolution:  10.00 A / 0.01 A
Accuracy:  1.0% + 3
   20 A overload for 30-seconds max
Hz (V or A input)2
Range/Resolution:  99.99 Hz / 0.01 Hz
Range/Resolution:  999.9 Hz / 0.01 Hz
Range/Resolution:  9.999 kHz / 0.001 kHz
Range/Resolution:  50 kHz / 0.01 kHz
Accuracy:  0.1% + 2

Notes:
1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F

2) Frequency is ac coupled, 5Hz to 30 kHz for ac voltage

Mechanical & General Specifications
Size
   167 x 84 x 46 mm (6.57" x 3.31" x 1.82")
Weight
   550 g
Warranty
   3 years

Model includes the following:

  • Holster
  • Installed 9 V battery
  • 4 mm silicone test lead set
  • User manual

Fluke 115

 

  • Large white LED backlight to work in poorly lit areas
  • Resistance and continuity
  • Frequency and capacitance
  • Maximum Voltage ac/dc 600V
  • 10A ac/dc current measurement (20 A overload for 30-seconds max)
  • Min/Max/Average to record signal fluctuations
  • CAT III 600 V safety rated

Safety conformance

All inputs are protected to CE, IEN61010-1 CAT III 600V. UL, CSA, TÜV listed and VDE.

 
   